我们的产品

耐用、可靠和性价比高

威尔顿气动隔膜泵不仅是经济、可靠和节能的理想解决方案,其先进的空气分配系统(ADS)通过减少耗气量和优化维护来显著提高正排量泵的生产率。

查看我们的产品

CHEM-FUSE节省计算器

个性化的节省成本计算

即可根据所填写的工业级隔膜和常规隔膜的标准平均故障间隔时间数据,查看您潜在可节省成本。

立即开始保存

专用泵

查看所有

我们的市场

威尔顿®解决各种泵送挑战。

威尔顿®正排量气动双隔膜(AODD)泵解决方案在诸多行业和应用中处于前沿地位。

查看我们的市场

支持与服务

威尔顿的全球服务和支持,提供超出预期的援助

威尔顿®时刻为威尔顿气动隔膜泵、零件或附件提供技术支持。

查看支持与服务选件

CHEM-FUSE节省计算器

个性化的节省成本计算

即可根据预填的工业级隔膜和常规隔膜的标准平均故障间隔时间数据,立即查看您的潜在节省成本。

立即开始保存

Dewatering with Air Operated Diaphragm Pumps

by PSG | 8月 30, 2018

Bulldozer in flooded area

Dewatering, or the removal of water, is a common application for AODD pumps.  Regardless of the industry or location in the plant water can accumulate in a variety of areas.

Construction sites can readily accumulate water as they are outside and exposed to the elements.  Rain can easily accumulate in a variety of areas and needs to be removed prior to the continuation of work.

Similarly, any loading dock without proper drainage would need to be cleared of water after a heavy rain.

Sumps are commonly found inside and outside manufacturing locations and are purposely installed so that water and other liquid wastes accumulate in a known area.  Outside in particular one may find sumps installed in order to prevent water runoff into the surrounding area.

Additionally, during Mining and Tunneling, ground water often accumulates and needs to be removed.

All of the above scenarios pose essentially the same problem.  Water accumulated in a set area and must be removed.  Because the area of water accumulation is often open, solids and other abrasives are present.  Sumps can often contain rocks, metal shavings and other such debris which can pose a problem to water removal.

Water removal is well suited to AODD pumps due to several essential features.  AODD pumps are self-priming.  All-Flo’s 2 inch model can prime itself up to 24.4 ft. In practice this is very useful as an operator can often drop a hose into a “water hole” and start dewatering immediately.

Caution must be taken to avoid damage to the diaphragms due to the presence of debris in the water.  Two practical steps can be taken to mitigate this risk.  Firstly, it is common to install a strainer to prevent very large debris from entering the pump.  This strainer however does not prevent small debris from entering the pump and causes damage.  Secondly, Thermoplastic Diaphragms should be used instead of rubber diaphragms whenever possible.  Historically a common diaphragm used for dewatering was Buna-N or Nitrile.  A good alternative to this material is the thermoplactic elastomer (TPE) Geolast®.  TPEs’ typically have twice the life of their rubber counterpart and are an excellent material when handling abrasives.  In many cases where small debris may puncture a rubber diaphragm, a Geolast® would come through unscathed.